3-7. Setting The Adjustment Values
3-7-1. Hi-MD3 setting
Preparation:
1. Perform calculation every item based on the data given by the
Hi-MD3 adjustment disc by referring to the following table.
(Round off the value in decimal place)
2. Convert the calculated value into hexadecimal number.
Note: The Hi-MD3 adjustment parameters vary depending on the disc,
and therefore use the parameters of the disc used when performing
the adjustment.
Item No. Calculating formula (*3)
0211 Pr_nominal / 0.05
(*1) Por / 0.05
0212 Kr × (100)
0213 Pw_nominal / 0.05
(*2) Ppw / 0.05
0214 Kw × (100)
0215 Prmin / 0.05
0216 Pwmin / 0.05
*1) If the “Pr_nominal” value is indicated, use the “Pr_nominal” value
and not used “Por” value.
*2) If the “Pw_nominal” value is indicated, use the “Pw_nominal” value
and not used “Ppw” value.
*3) Round off after the decimal point.
Table 3-7-1. Hi-MD3 adjustment parameter
Example of Calculation:
Item No. Parameter
Result
Decimal Hexadecimal
0211 Pr_nominal 2.50 mW 50 32h
0212 Kr 0.3 %/°C30 1Eh
0213 Pw_nominal 7.35 mW 147 93h
0214 Kw 0.4 %/°C40 28h
0215 Prmin 1.9 mW 38 26h
0216 Pwmin 5.8 mW 116 74h
Procedure:
1. In the test mode (Display Check mode), press the [VOL+] key
to enter the Manual mode.
2. Press the [FF] key once, press the [VOL+] key once, and press
the [FF] key once again to display as follows.
Display of the remote commander
3. Press the [FF] key once to select the item number 0211.
4. Adjust with [VOL+]/[VOL--] keys so that the adjustment value
of LCD becomes calculated value.
5. Press the X key to write the adjusted value.
6. Press the [FF] key to next item.
7. Repeat adjustment from step 4 until item number 0216.
3-7-2. Other setting
1. In the test mode (Display Check mode), press the [VOL+] key
to enter the Manual mode.
2. Press the [FF] key five time to select the item number 0113
and display as follows.
Display of the remote commander
3. Press the [VOL+]/[VOL--] key and set the according value to
each model type and destination referring to the following
table.
4. Press the X key to write the adjusted value.
Destination Setting value
US, Australian 01
AEP, UK 81
E18, Hong Kong, Taiwan,
Korean, Chinese, Tourist
05
Abbreviation
E18: 100V - 240V AC area in E model
Table 3-7-2. Mode Type and Destination Setting
3-8. Servo Overall Adjustment
Note1: Be sure to adjustment so that the set is horizontal and the LCD is
upside. Unless performed in that state, it is not adjusted correctly.
Note2: If NG is displayed in the middle of this adjustments, perform “3-2.
Initialize The Adjustment Value” and “3-7. Setting The Adjustment
Values” again, then retry this adjustments from step 1.
Procedure:
1. Insert the full charged lithium-ion battery (LIP-4WM)
and enter the test mode (Display Check mode).
2. Press the [VOL--] key to enter the Overall Adjustment mode.
3. Insert the CD adjustment disc (TDYS-1).
4. Put the main unit horizontal so that the LCD becomes upside,
and press the [FR] key.
5. Wait until “CD OK” is displayed on the LCD.
6. Insert the MD1/HiMD1 hybrid adjustment disc
(MDW-74/GA1).
7. Put the main unit horizontal so that the LCD becomes upside,
and press the [FF] key.
8. Wait until “MD1 OK” is displayed on the LCD.
9. Insert the Hi-MD3 adjustment disc (HMD1GSDJ).
10. Put the main unit horizontal so that the LCD becomes upside,
and press the [VOL+] key.
11. Wait until “HMD OK” is displayed on the LCD.
12. Eject the disc.
13. Put the main unit horizontal so that the LCD becomes upside,
and press the [VOL--] key.
14. Wait until “OfstOK” is displayed on the LCD.
15. Press the x key and back to the Display Check mode.