Troubleshooting
Others
Remote Commander
Others
Indicators
Warning Messages
Use the list below to check the meaning of the messages displayed on the screen.
Symptom Cause and Remedy
The Remote Commander
does not work.
The Remote Commander battery are dead.
c Replace them with new battery (see page 16).
Symptom Cause and Remedy
The control panel keys do
not function.
The control panel keys are locked.
c Unlock the control panel keys (see page 36).
Symptom Cause and Remedy
The LAMP/COVER
indicator flashes in orange.
(Repetition rate of 2
flashes)
The lamp cover or the air filter cover is detached.
c Attach the cover securely (see pages 43 and 44).
The LAMP/COVER
indicator flashes in orange.
(Repetition rate of 3
flashes)
The lamp has reached the end of its life.
c Replace the lamp (see page 42).
The lamp has reached a high temperature.
c Wait for 60 seconds to cool the lamp and then turn on the power
again.
:
/1 key flashes in red.
(Repetition rate of 2
flashes)
The internal temperature is unusually high.
c Check to see that nothing is blocking the ventilation holes.
The projector is being used at a high altitude.
c Ensure that “High Altitude Mode” in the Setup menu is set to
“On.
:/1 key flashes in red.
(Repetition rate of 4
flashes)
The fan is broken.
c Consult with qualified Sony personnel.
:
/1 key flashes in red.
(Repetition rate of 6
flashes)
Unplug the AC power cord from the wall outlet after the :/1 key
stops flashing, plug the power cord to the wall outlet, and then turn
the projector on again. If the ON/STANDBY flashes in red and the
problem persists, the electrical system has failed.
c Consult with qualified Sony personnel.
Messages List
Message Meaning and Remedy
Please replace the Lamp
and clean the Filter.
It is time to replace the lamp and clean the air filter.
c Replace the lamp (see page 42) and clean the filter (see
page 44).
When this message appears even after replacing the lamp, the task
has not been completed.
c Perform the operation of steps 10 to 13 on page 43
Page view 46