Sony Water Dispenser 2 User Manual Page 216

  • Download
  • Add to my manuals
  • Print
  • Page
    / 362
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 215
Chapter 16 Engineering Setup
216
Setup Relating to Operations From the Control Panel
Setting the action of the [SHIFT] button in the cross-point control
block
In the <Shift Mode> group of the Panel>Xpt Assign>Multi Xpt Assign menu,
select either of the following.
Display: Functions as a shift button dedicated to the source name displays.
Shift All Bus: Functions as a shift button for all buses.
Notes
It is not possible to make this setting separately for individual switcher
banks.
“Shift All Bus” is only valid when the cross-point button shift operation (see
previous item) is set to “Lock” or “Off.”
Exporting source names and destination names
To send the source names and destination names to the S-Bus, use the
following procedure.
1
In the Panel>XPT Assign menu, press [Name Export].
The Name Export menu appears.
2
Turn the knob to set the station ID.
a) If set to 255, the information is sent to all stations.
3
Press [Src Name Export].
This exports the source names to the station selected in step 2.
4
Press [Dest Name Export].
This exports the destination names to the station selected in step 2.
Note
Since destination names cannot be selected freely, fixed names are used.
AUX Delegation Buttons Settings (Aux Assign Menu)
To carry out the settings of the AUX delegation buttons in the auxiliary bus
control block, use the Panel>Aux Assign menu.
Knob Parameter Adjustment Setting values
1 Station ID Station ID setting
1 to 255
a)
Page view 215
1 2 ... 211 212 213 214 215 216 217 218 219 220 221 ... 361 362

Comments to this Manuals

No comments