Sony ICD-UX70 User Manual

Browse online or download User Manual for Dictaphones Sony ICD-UX70. Sony ICD-UX70 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 64
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
ICD-UX70/UX80 GB 3-274-295-13(1)
IC Recorder
Operating Instructions
© 2007 Sony Corporation
ICD-UX70/UX80
3-274-295-13(1)
Getting Started
Basic Operations
Various Recording Modes
Playback/Erasing
Editing Messages
Utilizing the Menu Function
Utilizing Your Computer
Troubleshooting
Additional Information
Index
Owners Record
The model number is located at the rear panel and the
serial number is located inside the battery compartment.
Record these numbers in the spaces provided below.
Refer to these numbers whenever you call upon your Sony
dealer regarding this product.
Model No.
Serial No.
Page view 0
1 2 3 4 5 6 ... 63 64

Summary of Contents

Page 1 - IC Recorder

ICD-UX70/UX80 GB 3-274-295-13(1)IC RecorderOperating Instructions© 2007 Sony CorporationICD-UX70/UX803-274-295-13(1)Getting StartedBasic OperationsVa

Page 2 - Declaration of Conformity

ICD-UX70/UX80 GB 3-274-295-12(1)10GBRemaining recording time indicationDisplays the remaining recording time in hours, minutes, and seconds.If there

Page 3 - Table of Contents

ICD-UX70/UX80 GB 3-274-295-12(1)11GB Getting StartedGetting StartedStep 1: Preparing a Power SourceInserting the battery1 Slide and lift the battery

Page 4 - Additional Information

ICD-UX70/UX80 GB 3-274-295-12(1)12GBWhen replacing/charging the batteryThe remaining battery indicator on the display shows the battery condition.Batt

Page 5 - Checking the contents

ICD-UX70/UX80 GB 3-274-295-13(1)13GB Getting StartedWhen using Sony NH-AAA rechargeable batteryRecording modeST*3STSP*4Recording Approx. 9 hr. Appro

Page 6 - Controls

ICD-UX70/UX80 GB 3-274-295-12(1)14GBNote while accessingThe IC recorder is accessing data when an updating animation appears in the display window or

Page 7

ICD-UX70/UX80 GB 3-274-295-12(1)15GB Getting Started1 Select “DATE & TIME” in the menu.Press and hold /MENU for more than one second. The men

Page 8 - Display window

ICD-UX70/UX80 GB 3-274-295-12(1)16GBBasic OperationsRecording Messages231Built-in microphones (headphone) jackOperation indicator11 Select a folder.

Page 9

ICD-UX70/UX80 GB 3-274-295-12(1)17GB Basic Operations3 Press  (stop) to stop recording.The IC recorder stops at the beginning of the current reco

Page 10

ICD-UX70/UX80 GB 3-274-295-12(1)18GBSelecting the recording modeSelect the recording mode in the “REC MODE” menu.ST : High-quality stereo recording m

Page 11 - Inserting the battery

ICD-UX70/UX80 GB 3-274-295-12(1)19GB Various Recording ModesVarious Recording ModesStarting to Record Automatically in Response to Sound – the VO

Page 12 - When replacing/charging

ICD-UX70/UX80 GB 3-274-295-12(1)2GBFor the customers in the United StatesThe following FCC statement applies only to the version of this model manufac

Page 13 - 44.1 kHz)

ICD-UX70/UX80 GB 3-274-295-12(1)20GBRecording with an External MicrophoneStereo microphone1 Connect an external microphone to the  (microphone) jack

Page 14 - Step 2: Setting the

ICD-UX70/UX80 GB 3-274-295-12(1)21GB Various Recording ModesRecording from Other EquipmentTape recorder, etc.1 Connect other equipment to the IC

Page 15 -  or  to

ICD-UX70/UX80 GB 3-274-295-12(1)22GB* Optional audio connecting cables (not supplied)To the IC recorderTo the other equipmentRK-G139 HG Stereo mini-p

Page 16 - Recording Messages

ICD-UX70/UX80 GB 3-274-295-12(1)23GB Playback/ErasingPlayback/ErasingPlaying Back Messages453 (headphone) jackA-B11DPCOperation indicator21 S

Page 17 -  (stop) to stop recording

ICD-UX70/UX80 GB 3-274-295-12(1)24GB5 Press  (stop) to stop playback.After playing back the last message in the selected folder, the IC recorder sto

Page 18 - Maximum recording time

ICD-UX70/UX80 GB 3-274-295-12(1)25GB Playback/ErasingWhen messages are played back to the end of the last messageWhen you play back or fast pla

Page 19 -  (record/pause) to pause

ICD-UX70/UX80 GB 3-274-295-12(1)26GBVarious playback modesYou can select “1 FILE” playback (one message/le is played back once), “FOLDER” playback (a

Page 20 - External Microphone

ICD-UX70/UX80 GB 3-274-295-12(1)27GB Playback/ErasingPlaying back a specied section repeatedly – A-B Repeat1 During playback, press (repeat

Page 21 - Equipment

ICD-UX70/UX80 GB 3-274-295-12(1)28GB3 Set the alarm date and time.Press the control key toward  or  to select “DATE,” a day of the week, or “DAIL

Page 22 - Recording sound from a

ICD-UX70/UX80 GB 3-274-295-12(1)29GB Playback/ErasingNotesYou can set only one alarm.When the clock has not been set or no messages are recorde

Page 23 - Messages

ICD-UX70/UX80 GB 3-274-295-12(1)3GBTable of ContentsChecking the contents of the package ...

Page 24 -  (stop) to stop playback

ICD-UX70/UX80 GB 3-274-295-12(1)30GBErasing messages one by oneYou can erase unwanted messages, retaining all other messages when the IC recorder is i

Page 25 -  while

ICD-UX70/UX80 GB 3-274-295-12(1)31GB Editing MessagesEditing MessagesMoving Message to a Dierent FolderNoteWhen “ ” is displayed for the fol

Page 26 - Pitch Control function)

ICD-UX70/UX80 GB 3-274-295-12(1)32GBUtilizing the Menu FunctionMaking Settings for the Menu2, 342, 311 Press and hold /MENU for more than one second

Page 27 - Time with an Alarm

ICD-UX70/UX80 GB 3-274-295-12(1)33GB Utilizing the Menu FunctionMenu settingsMenu items Settings Operation mode ( : the setting can be ma

Page 28 -  or  to set

ICD-UX70/UX80 GB 3-274-295-12(1)34GBMenu items Settings Operation mode ( : the setting can be made/: the setting can be made/  : the setting cannot

Page 29 - Erasing Messages

ICD-UX70/UX80 GB 3-274-295-12(1)35GB Utilizing the Menu FunctionMenu items Settings (*: Initial setting)REC MODE Sets the recording mode.ST

Page 30 - Erasing all messages in a

ICD-UX70/UX80 GB 3-274-295-12(1)36GBMenu items Settings (*: Initial setting)DISPLAY Changes the display mode.ELAPSE*:Elapsed playback time of one mess

Page 31 - Editing Messages

ICD-UX70/UX80 GB 3-274-295-12(1)37GB Utilizing the Menu FunctionMenu items Settings (*: Initial setting)EFFECT POP:Stresses middle ranges,

Page 32 - Utilizing the Menu Function

ICD-UX70/UX80 GB 3-274-295-12(1)38GBMenu items Settings (*: Initial setting)PLAY MODE Sets the playback mode.1 FILE:When a message is played back, the

Page 33 - Menu settings

ICD-UX70/UX80 GB 3-274-295-12(1)39GB Utilizing the Menu FunctionMenu items Settings (*: Initial setting)BACKLIGHT Turns the backlight in th

Page 34

ICD-UX70/UX80 GB 3-274-295-12(1)4GBUtilizing Your ComputerUsing the IC Recorder with Your Computer ...

Page 35 -  (record/pause) is

ICD-UX70/UX80 GB 3-274-295-12(1)40GBMenu items Settings (*: Initial setting)DETAIL MENUSELECT INPUT Selects the external input to be recorded that is

Page 36

ICD-UX70/UX80 GB 3-274-295-12(1)41GB Utilizing Your ComputerUtilizing Your Computer Your ComputerUsing the IC Recorder with Your Computer

Page 37 - . This function is useful

ICD-UX70/UX80 GB 3-274-295-12(1)42GBConnecting the IC recorder to your computerYou can transfer the IC recorder data onto your computer by connecting

Page 38

ICD-UX70/UX80 GB 3-274-295-12(1)43GB Utilizing Your ComputerNotesIf you connect more than two USB devices to your computer, normal operat

Page 39

ICD-UX70/UX80 GB 3-274-295-12(1)44GBNotesYou can use the transcribing feature only when you have installed Dragon NaturallySpeaking Select or Professi

Page 40

ICD-UX70/UX80 GB 3-274-295-12(1)45GB Utilizing Your ComputerTips on using the IC recorderWhen transcribing messages recorded using the IC

Page 41 - System requirements

ICD-UX70/UX80 GB 3-274-295-12(1)46GB1 Connect the IC recorder to your computer (page 42).On the Windows screen; open “My Computer” and make sure that

Page 42 - Connecting the IC recorder

ICD-UX70/UX80 GB 3-274-295-12(1)47GB Utilizing Your ComputerConstruction of folders and lesThe folders and les are displayed on the com

Page 43 - Introducing the voice

ICD-UX70/UX80 GB 3-274-295-12(1)48GB*1 The name of a folder in which MP3 files are stored will be displayed on the IC recorder as it is, so it is conv

Page 44 - (Training)

ICD-UX70/UX80 GB 3-274-295-12(1)49GB TroubleshootingTroubleshootingTroubleshootingBefore taking the IC recorder for repair, check the f

Page 45 - Using the IC Recorder

ICD-UX70/UX80 GB 3-274-295-12(1)5GBChecking the contents of the packageIC Recorder (1) LR03 (size AAA) alkaline battery (1) Stereo headphones (1)

Page 46 - and then drop

ICD-UX70/UX80 GB 3-274-295-12(1)50GBSymptom Remedy“FILE FULL” is displayed and you cannot operate the IC recorder.99 messages have been recorded in th

Page 47 - Construction of folders and

ICD-UX70/UX80 GB 3-274-295-13(1)51GB TroubleshootingSymptom RemedyThere are fewer menu items displayed in the menu mode.The menu items

Page 48

ICD-UX70/UX80 GB 3-274-295-12(1)52GBError messagesError message Cause/RemedyBATTERY LOW You cannot format the memory or erase all the les in a folder

Page 49

ICD-UX70/UX80 GB 3-274-295-12(1)53GB TroubleshootingError message Cause/RemedySET DATE&TIME Set the clock; otherwise, you cannot se

Page 50

ICD-UX70/UX80 GB 3-274-295-12(1)54GBSystem limitationsThere are some system limitations of the IC recorder. Troubles as mentioned below are not malfun

Page 51

ICD-UX70/UX80 GB 3-274-295-12(1)55GB Additional InformationAdditional InformationRecording with Other EquipmentTape recorder, etc.To

Page 52 - Error messages

ICD-UX70/UX80 GB 3-274-295-12(1)56GBUsing a USB AC Adaptor (not supplied)USB connector of the IC recorderUSB AC adaptor (not supplied)You can connect

Page 53

ICD-UX70/UX80 GB 3-274-295-12(1)57GB Additional InformationNotesDuring recording (the operation indicator lights or flashes in red) o

Page 54 - System limitations

ICD-UX70/UX80 GB 3-274-295-12(1)58GBOn noiseNoise may be heard when the unit is placed near an AC power source, a uorescent lamp or a mobile phone du

Page 55 -  (headphone)

ICD-UX70/UX80 GB 3-274-295-13(1)59GB Additional InformationSpeakerApprox. 10 mm (13/32 in.) dia.Power output90 mWInput/OutputMicropho

Page 56

ICD-UX70/UX80 GB 3-274-295-12(1)6GBIndex to Parts and ControlsRefer to the pages indicated in parentheses for details.FrontRearOperation indicator (

Page 57 - Precautions

ICD-UX70/UX80 GB 3-274-295-12(1)60GBIndexAA-B Repeat ...27Adjusting the volume ...

Page 58 - Specications

ICD-UX70/UX80 GB 3-274-295-12(1)61GB IndexMMaintenance...58MenuALARM

Page 59

ICD-UX70/UX80 GB 3-274-295-13(1)62GBSSetting the Clock ...14SP ...

Page 60

ICD-UX70/UX80 GB 3-274-295-12(1)63GB Index

Page 61 - Index

ICD-UX70/UX80 GB 3-274-295-13(1)Printed in China

Page 62 - Trademarks

ICD-UX70/UX80 GB 3-274-295-12(1)7GB (record/pause) button (16, 17, 19, 35) (stop) button (17, 24, 25, 28, 31, 32) (cue/fast forward) button (

Page 63

ICD-UX70/UX80 GB 3-274-295-12(1)8GBDisplay windowOperation mode indicatorDisplays the following, depending on the current operation mode : stop : pl

Page 64 - Printed in China

ICD-UX70/UX80 GB 3-274-295-12(1)9GB : review/fast backward, cue/fast forward : going backward/forward continuously Folder name/ Message title name

Comments to this Manuals