186 Other Settings
Chapter 9 System Settings
To delete parallel tally settings
In step 2, select a tally port and press [Clear].
Making wiring settings
When configuring a system in which the switcher inputs
and outputs are connected to a router, it is necessary to set
up this connection configuration (referred to as “wiring”)
in the S-Bus space.
To make new wiring settings
1
From the top menu, select Setup/Diag >System Tally
Wiring.
The Wiring menu appears. The status areas shows
wiring information.
2
Press [New], turning it on, and turn the knobs to set the
following parameters.
3
Press [Set].
To modify wiring settings
1
If [New] is on, turn it off.
2
Using any of the following methods, select the wiring
setting to modify.
Press directry on the list in the status area.
Use the arrow buttons to scroll the reverse video
cursor.
Turn the knob.
3
Turn the knobs to set the following parameters.
4
Press [Set].
To sort wiring settings
1
Select a wiring setting by carrying out steps 1 and 2 of
“To modify wiring settings,” then press [Sort].
A popup window appears.
2
Execute the sort by selecting one of the following sort
orders.
Dest: Destination level/address
The wiring settings are sorted as follows.
Ascending order (smallest first) by destination
level t ascending order by destination address
t ascending order by source level t ascending
order by source address.
Source: Source level/address
The wiring settings are sorted as follows.
Ascending order (smallest first) by source level
t ascending order by source address t
Ascending order by destination level t
ascending order by destination address.
To delete wiring settings
Select a wiring setting by carrying out steps 1 and 2 of “To
modify wiring settings,” then press [Delete].
Copying tallies
You can copy tally source information to another tally
source.
To make new tally copy settings
1
From the top menu, select Setup/Diag >System Tally
>Tally Copy.
The Tally Copy menu appears. The status area shows
the current tally copy settings.
Knob Description Setting values
1 (Dest From) Destination start
address
1 to 1024
2 (Dest To) Destination end
address
1 to 1024
3 (Dest Lvl) Destination level 1 to 8
4 (Src From) Source start address 1 to 1024
5 (Src Lvl) Source level 1 to 8
Knob Description Setting values
1 (No) Wiring number selection 1 and upwards
Knob Description Setting values
2 (Dest Add) Destination address 1 to 1024
3 (Dest Lvl) Destination level 1 to 8
4 (Src Add) Source address 1 to 1024
5 (Src Lvl) Source level 1 to 8