Page view 42
Administrating the Camera
Setting the Schedule — Schedule setting Page / Setting the Schedule — Schedule setting Page
43
Notes
When you control the camera via the serial port using
the VISCA protocol, match the communication
settings with those on the connected controller.
This camera does not support the daisy chain
connection of VISCA devices. Connect the camera
and the controller one for one.
TCP port No.
When you select TCP on the Mode menu, type the port
number for the TCP port (TCP Generic Driver). Set a
port number other than Well-Known port numbers (0 to
1023).
Baud rate
Select the communication baud rate for the peripheral
device connected to the serial interface. You can select
from among the following baud rates:
38400, 19200, 9600, 4800, 2400, 1200, 600, 300 (bps)
Parity bit
Select the parity bit for the peripheral device connected
to the serial interface: None, Odd or Even.
Character length
Select the character length for the peripheral device
connected to the serial interface: 7 or 8 (bits).
Stop bits
Select the stop bit for the peripheral device connected to
the serial interface: 1 or 2 (bits).
OK/Cancel
See “Buttons common to every setting page” on page
17.
Setting the Schedule
— Schedule setting Page
When you click Schedule on the Administrator menu,
the Schedule setting page appears.
Use this page to set up to six schedules used for the Day/
Night function, FTP client function, SMTP function,
Alarm out 1 or 2 function and Image memory function.
Schedule No. 1 to Schedule No. 6
For each schedule, specify Start time (hour and minutes)
and End time (hour and minutes), and check the days of
the week that you want to activate the function.
OK/Cancel
See “Buttons common to every setting page” on page
17.
Page view 42