DATA PROJECTORSRX-T420INSTALLATION MANUAL1st Edition
1-4SRX-T420Panel (U5)ScrewsScrewsHooksPanel (U1B)ScrewsFig. 1-1-6Fig. 1-1-71-1-6. Panel (U5)1. Remove the panel (U7) block assembly. (Refer to Sectio
1-5SRX-T420ScrewsPanel (U1)ScrewsScrewsScrewsFig. 1-1-81-1-8. Panel (U1)1. Remove the panel (U7) block assembly. (Refer to Section 1-1-2.)2. Remove
1-6SRX-T420M8boltsJackJackM8 boltsHolesAdjuster pipe assemblyAdjuster pipe assemblyJackFramenWhen setting the jack, pay attention to the holes on the
1-7SRX-T420AdjusterAnchor BKTDuct connection8-inch ductFig. 1-2cFig. 1-3In the case of fi xing this unit:This unit can be fi xed to the fl oor using the
1-8SRX-T420BoltsFocus cableZoom cablePOTENTIO cableProjection lensPinsProjectionlensNotch LineTighten the bolts in the order from to .Lens brac
1-9SRX-T420HookHolesConvex portionsHoleHoleConvexportionsLens coverLens coverLens coverHookHookLens coverHookHookHookFig. 1-5aFig. 1-5b1-5. Installin
1-10SRX-T420AdjusterProtection suitArm coverHoodFace shieldFace shieldGloveArm coverGloveFig. 1-6a1-6. Installing the Lamp Bulbw. Be sure to turn of
1-11SRX-T420ScrewAnode harnessPortion ALamp bulbAnode harnessAnode sideScrewFig. 1-6bFig. 1-6cProcedurem. Keep the serial code label affi xed on the O
1-12SRX-T420Panel (U4) block assembly (420)LockScrew(withdrop-safe)Screw(with drop-safe)Cold mirror assemblyCold mirror assemblyScrews (with drop-safe
1-13SRX-T420Cathode terminalHexagon socket set screwAnode terminalBoltFig. 1-6e6. Remove the bolt from the anode terminal.7. Loosen the hexagon sock
SRX-T420! 警告このマニュアルは,サービス専用です。お客様が,このマニュアルに記載された設置や保守,点検,修理などを行うと感電や火災,人身事故につながることがあります。危険をさけるため,サービストレーニングを受けた技術者のみご使用ください。! WARNINGThis manual is in
1-14SRX-T420Protection sheetLamp bulbFig. 1-6g9. Remove the protection sheet from the lamp bulb.10. Loosen the knob, then move the anode holder in t
1-15SRX-T420Cathode terminalHexagon socket set screwAnode terminalBoltAnode holderAnode harnessKnobCathode terminalEnd faceSurface CLamp bulbAnodehold
1-16SRX-T420LKRI-003B3 x 8Finger holder (HIF)Panel (HIF-44)LKRI-003B3 x 8Fixed plate (HIF) 320HandleHandleFig. 1-7aFig. 1-7b1-7. Installing the Optio
1-17SRX-T420INPUT BLKRI-003PSW4 x 10Panel cover (IF) 420PSW4 x 10PSW4 x 10Panel cover (IF) 420Blank panelFig. 1-7cFig. 1-7d4. Remove the six screws,
1-18SRX-T420LKRI-005B3 x 8Finger holder (DIF)Panel (DIF-188)LKRI-005B3 x 8Fixed plate (DIF) 320HandleHandlePSW4 x 10PSW4 x 10Panel cover (IF) 420Blank
1-19SRX-T420INPUT BLKRI-005PSW4 x 10Panel cover (IF) 420Fig. 1-7hWhen attaching the LKRI-005 to INPUT B slot6. Insert the LKRI-005 board into INPUT B
1-20SRX-T420Fig. 1-7iSRW-5000HD DIGITAL VIDEO CASSETTE RECORDERLKRI-003To HD-SDI output terminalHD-SDI connecting cable (optionally available)To IN te
1-21SRX-T420In case of LKRI-005m. For INPUT A slot, LKRI-005 is installed by default. However, LKRI-003 can be installed.. When using a long cable, t
1-22SRX-T4201-8. Interlock TerminalPin locationInterlock terminal1. Interlock FunctionThe SRX-T420 interlock function is enabled by making the two pin
1-23SRX-T420Pattern 2Normal: ShortInterlock: OpenOpen/short between pin 5 and pin 6 with the pin 3 and pin 4 shorted state1-9. Connecting and Wiring
1SRX-T420Table of Contents2. Adjustment2-1. Installation of SRX Controller ... 2-22-1-1. Startup ...
1-24SRX-T4201-10. Connecting the Power CordUse the 3-core power cord that satisfy AWG 8, 250 V rated and 40 A rated. Connect the power cord to the A
1-25SRX-T420ScrewGround wireGround terminalPack by solderingScrewsGround terminalCable clampScrewFig. 1-10cFig. 1-10d5. Pack by soldering the end of
1-26SRX-T4201-11. About the Optional AccessoriesThe projection lamps of this projector are provided as optional accessories. Install the lamp houses
1-27SRX-T4201-12. Projection Distance ChartsThe alphabetical characters in this section indicate the following measurements:W: Screen width (unit: m
1-28SRX-T420The formula for calculating the projection distance from the screen diagonal length (D, unit: inch) is as follows:Type of lens Projection
1-29SRX-T420When projecting a 3840-pixel (aspect ratio 16:9) image at the maximum horizontal picture element Unit: mm (inches)W 4500 5000 6000 7000
1-30SRX-T420Using the LKRL-Z140 projection lensWhen projecting a 4096-pixel (4K x 2K) image at the maximum horizontal picture element Unit: mm (inche
1-31SRX-T420When projecting a 2880-pixel (aspect ratio 4:3) image at the maximum horizontal picture element Unit: mm (inches)W 3500 4000 4500 5000
1-32SRX-T4201-13. Dimensions LeftExhaustFront(Barycentricposition)(Barycentricposition)
1-33SRX-T420Signal cable(For the unit fixing)AC power cable*(Optional lens) *LKRL LIST(Barycentric position)Top(Barycentric position)RightIntakeIntake
2-1SRX-T420Section 2Adjustment1. Install an SRX Controller in an adjusting personal computer. (Refer to Operating Instructions.)5. Perform illumin
2-2SRX-T420Fig. 2-1-1bFig. 2-1-1aEthernet cable (cross cable) (supplied)To Ethernet connectorPCShield case assembly (1)NETWORKconnector2-1. Installat
2-3SRX-T420Required equipment. PC- CPU: Intel Pentium M 1.6 GHz or more, and OS-recommended- RAM capacity: 256 MB or more, 512 MB or more recommen
2-4SRX-T4202-1-2. Function MemoryYou can register the settings that have been adjusted in the control windows to FUNCTION 1 to 7. As the default setti
2-5SRX-T420Fig. 2-2-12-2-1. Owner InformationThe information about this unit is set.OwnerName: Type the name of owner.Organization: Type the name of
2-6SRX-T420Fig. 2-2-22-2-2. Date & TimeThe current time is set.Time Zone: Select the zone that the unit is installed.Adjust clock for daylight s
2-7SRX-T420Fig. 2-2-32-2-3. NetworkThe connection to the network is set.Internet Protocol (TCP/IP): Select either one of the following.. Obtain an IP
2-8SRX-T420Fig. 2-2-42-2-4. Mail ReportThe sending of mail for the lamp bulb operating time and the maintenance information is set.Reporting TimingLam
2-9SRX-T420Fig. 2-2-52-2-5. PC CommunicationThe communication between this unit and PC is set.Projector Identifying: Setting of this unitPort No: Ty
3SRX-T420Manual StructurePurpose of this manualThis manual is the installation manual of Data Projector SRX-T420.This manual is intended for use by tr
2-10SRX-T420Fig. 2-2-62-2-6. SNMPSNMP (Simple Network Management Protocol) is set.SNMPsysName: Type the character string of standard MIB sysName.Cont
2-11SRX-T420Fig. 2-2-72-2-7. Profi leThe setting value of this unit is stored in PC, or the setting value stored in PC is written in this unit.Save: P
2-12SRX-T4202-3. Optical Axis Adjustment of Lamp BulbProcedure1. Be sure to click the “SERVICE” tab in the standby state. The SERVICE window is dis
2-13SRX-T4206. Click the “INSTALLATION” tab. The INSTALLATION window is displayed.7. Set the lamp power to 100% in the “LAMP POWER” menu to project
2-14SRX-T42012. In the same way, adjust the X-axis and Y-axis direction adjusting screws so that the value of the internal lumi-nance sensor becomes
2-15SRX-T4202-4. Lens Adjustment (H Shift, V Shift, Zoom, and Focus)Procedure1. Project a test pattern on the INSTALLATION window.2. Loosen the fou
2-16SRX-T420nSet the V shift amount within 1/2 screen. If it exceeds 1/2 screen, the zoom is changed, the image position may not be positioned at same
2-17SRX-T4202-5. Illumination Area Adjustment and Registration Adjustment2-5-1. Illumination Area AdjustmentIf there is any deviation of illuminatio
2-18SRX-T4205. Open the panel duct in the direction of the arrow.6. Remove the two screws, then remove the panel duct cover (upper).7. Remove the t
2-19SRX-T4209. Set Lamp Power to 53% in the “LAMP POWER” menu on the INSTALLATION window of SRX Con-troller immediately after the lamp is lit.10. Pr
2-20SRX-T420“COLOR SPACE CONVERTER” menuFig. 2-6-12-6. Color Space Conversion (CSC Adjustment)The color space of this unit can be corrected for each
2-21SRX-T420“COLOR SPACE CONVERTER” menuFig. 2-6-212. Check that the difference between the value measured in step 11 and the “Target Color Gamut” va
2-22SRX-T420Fig. 2-7-1a12. Check that the difference between the value measured in step 11 and the “Target Color Gamut” value is within the margin
2-23SRX-T420. MASKING ADJUST Adjusts the image masking according to the screen shape by the six adjusting point respectively. And adjustment value is
2-24SRX-T420 Fig. 2-7-2. MUTING Operates to close and open of the douser. - [ON] button: Close the douser. (Muting condition) - [OFF] button:
2-25SRX-T420 LENS CONTROLAdjusts the image projected on the screen.. Zoom: Adjusts the size of an image. An image is expanded when you click the
2-26SRX-T420 Fig. 2-7-3a2-7-3. SERVICE Window WHITE BALANCE REGISTRATION ADJUST LAMP ADJUST & TIMER RESET AIR FILTER TIMER INTERPOLA
2-27SRX-T420 REGISTRATION ADJUSTMoves R (red), G (green), and B (blue) in the horizontal and vertical directions by two pixels (maximum) one pixel at
2-28SRX-T420 INTERPOLATIONSwitches the interpolation function during the projection of 2K-resolution image.. On: Projects the high-resolution pictu
3-1SRX-T420Section 3Error MessageThe following messages are displayed in the status message display at the back of the main unit and the “Warning Info
1-1SRX-T420Section 1InstallationPanel (U8)Front sideRear sidePanel (U7) block assemblyPanel (U2) block assemblyPanel (U4) block assembly (420)Panel (U
3-2SRX-T420ALERT (Degree of risk: high)Message No. Error message Trouble RemedyALERT_01 BOARD ERROR The power of IFA board is defective. Check the IFA
3-3SRX-T420Message No. Error message Trouble RemedyALERT_33 BALLAST ERROR The power unit for lamp fan is abnormal. Check the power unit for lamp fan.
3-4SRX-T420Message No. Error message Trouble RemedyWARN_26 DOUSER ERROR DOUSER operation is failed. Check the connector of a shift block. Check the s
3-5SRX-T420Message No. Error message Trouble RemedyFAIL_19 LENS ERROR Focus operation is failed. Check the lens and lens cable. Check the SY board. Re
3-6SRX-T420nFan locationTop view7 Front sideLamp fan ALamp fan BLamp fan CLamp fan DPeltier R fanPeltier G fanPeltier B fanDSTboardFilter coverPBS
Sony CorporationSRX-T420 (SY) E9-968-662-01Printed in Japan2009. 10 22©2009
1-2SRX-T420Panel (U7) block assemblyLockHooksFig. 1-1-2GrillesScrews(withdrop-safe)Panel (U2) block assemblyHooksHooksHooksScrewsFig. 1-1-31-1-2. P
1-3SRX-T420Panel (U3)ScrewsHooksPanel (U6)HooksHooksScrewsFig. 1-1-4Fig. 1-1-51-1-4. Panel (U3)1. Remove the panel (U7) block assembly. (Refer to S
Comments to this Manuals